Simple and User-friendly Software

Parallel and Independent Operation of Each Channel by a group or a single person.

EPCLC W-Prep 2XY


Two chromatograms (Ch-1 & Ch-2) can be viewed on the same display at the same time.

EPCLC W-Prep 2XY


    

State-Of-The-Art Software Based On True Theory of Chromatography

Yamazen's proprietary automatic method set-up is based on true theory of the chromatography, thus achieves Gradient optimization.



Green Flash Chromatography

     Linear gradient is set with Rf value on TLC. (Rf gradient)

     The optimum method can be automatically developed to elute the target compound at around 4-Column Volume.

     Yellow arrow(s) predicts the eluting position of the target compound(s).


AI-580S Click to enlarge the image


     With the use of an Inject (Loading) Column, sample loading can be easily done without any sample loss. No cross contamination.

AI-580S

     Yamazen's UV detector monitors chromatogram in a broad OD range.
No Peak Saturation, No Sample Loss.

When running a small size sample and/or a sample that has low UV absorption;
AI-580S

Sample: Butyl p-hydroxybenzoate, 0.5mg Methyl p-hydroxybenzoate, 0.5mg Toluene, 9mg
Column used: Yamazen's Hi-Flash, L (30 gram) Fractionation mode: Peak mode separation



When running a large scale sample and/or a sample that has high UV absorption;
AI-580S

Sample: Butyl p-hydroxybenzoate, 500mg Methyl p-hydroxybenzoate, 500mg Toluene, 900mg
Column used: Yamazen's Hi-Flash, 2L (45 gram)   Fractionation mode: Peak mode separation



     It's possible to get a slow gradient from 1% to 7% of polar solvent.

AI-580S

A solvent delivery pump is of high precision medium pressure valveless ceramic piston pump, featuring infinite fine flow adjustments. The gradient at low concentration of solvent as low as 1 to 7% is possible, which is required when using a high polar solvent, like methanol, without pre-mixing.

Effective ceramic piston movement for maximum solvent and bubble clearing, assuring accurate solvent delivery. Bubbles produced by solvents that have low boiling points like dichloromethane will not affect pump.



     Real Time Pressure Monitor

AI-580S

The precision pressure meter makes it possible to do real time monitoring of the pressure building up inside the columns. Pressure moderation system (PMS) protects disposable plastic column and glass column from bursting.

Safety First

Yamazen's motto is "Safety First!"

Safety First

     Modular & Open System: easy to maintain and service

go to top

System Specifications


Pump (with an integrated mixer)
Model No. 580D
Flow Path Two Flow Paths (Independently controlled)
Number of Pump Head Two (Independently controlled)
Flow Rate 0~80ml/min (Independently controlled by PC)
Rated Pressure 1.0 Mpa
Number of solvents mixed Two solvents (Selection from 4 solvents. PC controls each path independently.)
Dimensions 180Wx394Dx317mmH
Weight 14Kg
Fixed Wavelength UV Detector
Model No. prepUV-254W
Range 0.08-5.12 AUFS
Flow Path Two (Independently controlled)
Light source Hg lamp
Wavelength 254nm
Output to recorder 10mVFS
Output to integrator 0-5.12V/AU
Out to D-sub Purpose-built signal
Dimensions 180Wx394Dx160mmH
Weight 7Kg
Variable Wavelength UV Detector
Model No. prepUV-10VW
Flow Path Two (Independently controlled)
Light source D2 lamp
Wavelength 190-360nm
Range 0.08-5.12 AUFS
Output to recorder 10mVFS
Output to integrator 0-5.12V/AU
Out to D-sub Purpose-built signal
Dimensions 180Wx400Dx135mmH x 2ea
Weight 7.5Kg x 2ea
UV/Visible Detector
Model No. PrepUV/Visible-10VW
Flow Path Two (Independently controlled)
Light source D2 lamp
Wavelength 190-600nm
Range 0.08-5.12 AUFS
Output to recorder 10mVFS
Output to integrator 0-5.12V/AU
Out to D-sub Purpose-built signal
Dimensions 180Wx400Dx135mmH x 2ea
Weight 7.5Kg x 2ea
Fraction Collector
Model No. FR-260
Detecting Flow Path Two (Independently controlled)
Number of Rack Two (One for each channel)
Driving mode X-Y driven, independently controlled, dual channel
Fraction mode Time Mode, Peak Mode, Peak & Slope mode
(Each rack is controlled independently by PC)
Input Signal Purpose-built signal
Dimensions 320Wx480Dx520mmH
Weight 23kg
System Controller (built into Fraction Collector)
Input/Output Signal Pump, Detector, Fraction collector, PC Serial Interface
PC Specifications
OS Windows XP, 7 (32bit)
CPU Pentium III or Mobile Celeron with 500MHz or more or Atom D410 is recommend.
Memory 1GB or more
Monitor Recommended XGA or higher resolution
Hard Disk Space At least 150GB of availability memory
Input/Output Signal Serial RS232C D-sub 9 pin or USB. (for USB, an adaptor is required)
Others Input device (Keyboard, Mouse)

go to top

Standard Accessories

FR-260 Rack
107Wx335Lx159mmH

FR-260 Fraction Collector holds two racks - either two of the same size rack for both channels or one each of the different size rack for each channel. Unless otherwise specified, two WP18150, 18x150mm racks, will be supplied with the system as standard accessory.

Note:
Specifications can change without notice.

Rack Specifications, Collection Tube (O.D. x Length x Quantity)
Cat. No.
Size Code
Fraction Volume(Default)
American Standard Tube Size (mm)
WP13100
A
7ml
13x100x60 pieces
WP15125
A
12ml
15x125x60 pieces
WP16125
A
15ml
16x125x60 pieces
WP16150
A
16ml
16x150x60 pieces
WP18150
B
22ml
18x150x60 pieces
WP25150
C
45ml
25x150x30 pieces
WP25200
C
56ml
25x200x30 pieces
WP20150
D
27ml
20x150x52 pieces
WP30200
E
100ml
*30x200x27 pieces
Note: Test tube with * is of Japanese standard (E-size).

Cat. No.
Size Code
Fraction Volume(Default)
Japanese Standard Tube Size (mm)
WP15150
A
15ml
15x150x60 pieces
WP18180
B
30ml
18x180x60 pieces
WP24180
C
60ml
24x180x30 pieces
WP21180
D
42ml
21x180x52 pieces
WP30180
E
90ml
30x180x27 pieces
WP30200
E
100ml
30x200x27 pieces


Fittings & Tubing

Options
Solvent Level Monitor
Waste Fluid Monitor
External Nozzle Cleaning System
Column Air Purge
TLC Image Reader


download brochure(PDF) EPCLC W-Prep 2XY