Intelligent & Eco-Friendly
AI-580 A-1 Type
Single Channel Automated Flash Chromatography System
- This model saves floor space by putting solvent bottles on top of the system.
- Column stand installed in front of pump/UV detector.
- Two solvent bottles (A & B or C & D) can be put on top of the Fraction Collector or four bottles, on the bench beside the pump or on the floor.
- Laptop computer can be put on the bench beside the machine or outside of the safety cabinet.
Capabilities and Functions
- Automatic method setup based on TLC data (Rf & solvent).
- Eluting position predictable: The target compound will always elute at around 4 column volume, regardless of column size and flow rate.
- Software gives the sample load information - automatic scale up or down.
- Method change during run - Click & drag up/down or sideways.
- Simple and easy change of running parameters on the fly.
- Easy change-over of the collection modes; Time, Peak, Peak & Slope, and Manual Collect, during run.
- Powerful UV detector: Can be used in a wide OD range of 0.08-5.12. Capable of detecting up to 4.0 AUFS.
- 4 different solvent systems (A & B, A & C, B & D, C & D) can be selected during run to change the solvent system for an increased run efficiency.
- Low concentration (slow) gradient (1-5% polar B solvent) is possible over a wide range of flow rate 3-80ml/min.
- Pressure moderating system to continue a run when pressure builds up suddenly .
- Real time monitoring of %B on the gradient when ramping up, to see the behavior of the sample in the solvent mixture.
System Specifications
| Solvent Delivery Pump | |
| Model | No.580 |
| Flow rate | 0-80ml/min. |
| Rated pressure | 1.0 Mpa (145 psi) |
| No. of solvent mixed | 2 (Choose from 4 solvents) |
| Dimension | 180Wx394Dx250mmH |
| Weight | 10 kg |
| Fixed Wavelength UV Detector | |
| Model | prepUV-254 |
| Light source | Hg lamp |
| Wavelength | 254nm |
| Range | O.D. 0.08-5.12 |
| Output to recorder | 10mVFS |
| Output to integrator | 0-5.12V/AU |
| Output to D-sub | Purpose built signal |
| Dimension | 180Wx394Dx135mmH |
| Weight | 6 kg |
| Variable Wavelength UV Detector | |
| Model | prepUV-10V |
| Light source | D2 lamp |
| Wavelength | 190-350nm |
| Range | O.D. 0.08-5.12 |
| Output to recorder | 10mVFS |
| Output to integrator | 0-5.12V/AU |
| Output to D-sub | Purpose built signal |
| Dimension | 180Wx460Dx135mmH |
| Weight | 10 kg |
| UV Visible Detector | |
| Model | prepUV-VIS-10V |
| Wavelength | 190-600nm |
| Fraction Collector | |
| Model | FR-360 |
| No. of Rack | 2 (A pair of the same size rack) |
| Driving mode | X-Y driven |
| Fraction mode | Time, Peak, Peak & Slope (Valley), Manual Collect |
| Input signal | Purpose-built signal |
| Dimension | 320Wx430Dx520mmH |
| Weight | 18 kg |
| System Controller (built into Fraction Collector) | |
| Input/Output Signal | Pump, Detector, Fraction Collector, PC dedicated |
| PC Specifications | |
| OS | Windows |
| CPU | Pentium III or Celeron with 500MHz or more is recommended. |
| Memory | 512MB or more |
| Monitor | XGA or higher resolution recommended |
| Hard Disk Space | Min 500MB of available memory |
| Input/Output Signal | Serial RS232C D-sub 9 pin |
Standard Accessories
A pair of the same size rackFR-360 Rack
118Wx335Lx159mmH
Note: FR-360 fraction collector holds a pair of the same size racks.
When ordering the rack, please specify it with Cat. Number.
Rack Specifications, Collection Tube (O.D. x Length x Quantity)
Cat. No. |
Pin Code |
Fraction Volume(Default) |
American Standard Tube Size (mm) |
AI13100 |
A |
7ml |
13x100x75 pieces |
AI15125 |
A |
12ml |
15x125x75 pieces |
AI16125 |
A |
15ml |
16x125x75 pieces |
AI16150 |
A |
16ml |
16x150x75 pieces |
AI18150 |
B |
22ml |
18x150x75 pieces |
AI25150 |
C |
45ml |
25x150x30 pieces |
AI25200 |
C |
56ml |
25x200x30 pieces |
AI30200 |
D |
100ml |
*30x200x27 pieces |
AI60180 |
E |
350ml |
*60x180x10 pieces |
Cat. No. |
Pin Code |
Fraction Volume(Default) |
Japanese Standard Tube Size (mm) |
AI15150 |
A |
15ml |
15x150x75 pieces |
AI18180 |
B |
30ml |
18x180x75 pieces |
AI24180 |
C |
60ml |
24x180x75 pieces |
AI30180 |
D |
90ml |
30x180x27 pieces |
AI30200 |
D |
100ml |
30x200x27 pieces |
AI16180 |
E |
350ml |
60x180x10 pieces |
Column Stand
Two types are available.
(1) Two square pillars installed parallel in front of pump
(2) Two round pillars installed parallel in front of pump
Fittings & Tubing
Options
Solvent Level Monitor
Waste Fluid Monitor
Column Air Purge Pump