Single Channel Automated Flash Chromatography System

AI-580 A-2 type
  • User-friendly, Simple Operation
  • Auto Setup of Optimum Chromatographic Method
  • Elution position of Target compound can be predicted at around end of gradient or 4 column Volume.
  • Powerful UV detector: Chromatogram can be viewed in a broad OD range. Neither peak saturation nor sample loss.
  • Accurate low (slow) gradient (1-7% polar solvent)
  • Real time monitor of the line pressure ensures safe operation.
  • Column stand installed in front of pump/UV detector.
  • Four solvent bottles will be put on the bench beside the pump or on the floor.
  • Laptop computer can be put on the top of the fraction collector or on the bench beside the machine or outside of a fume hood.

Eco-Friendly

Fast, Efficient, Safe Operation

and Eco-Friendly System



    

User-friendly Software with Ample Functions and Capabilities

AI-580 A-2 type Click to enlarge the image

     With the use of an Inject (Loading) Column, sample loading can be easily done without any sample loss.

AI-580 A-2 type

     Real Time Pressure Monitor

AI-580 A-2 type

The precision pressure meter makes it possible to do real time monitoring of the pressure building up inside the columns. Pressure moderation system (PMS) protects disposable plastic column and glass column from bursting.

Safety First

Yamazen's motto is "Safety First!"

Safety First

     Modular & Open System: easy to maintain and service



    

State-Of-The-Art Software Based On True Theory of Chromatography

     The optimum method can be automatically developed to elute the target compound at around 4-Column Volume.

     Yellow arrow(s) predicts the eluting position of the target compound(s).


AI-580 A-2 type Click to enlarge the image


     2-Step Gradient separates multiple compounds efficiently.

2-Step Gradient is the best method to use when separating two target compounds, of which TLC Rf values (Rf1&Rf2/(3)&(6)) are far apart from each other (ΔRf>0.3) with some other compounds in between. As Fig 1 shows, 2-Step Gradient purifies multiple compounds efficiently while achieving a high resolution. And Rf1 (Sample 3) and Rf2 (Sample 6) elute at 4 to 5 column volume on each gradient.
AI-580 A-2 type

Compared with the conventional ISOCRATIC method, 2-Step Gradient method shortens run time considerably, saves solvents and energy, and boosts productivity, therefore, It is eco-friendly.



     Yamazen's UV detector monitors chromatogram in a broad OD range.
No Peak Saturation, No Sample Loss.

When running a small size sample and/or a sample that has low UV absorption;
AI-580 A-2 type

Sample: Butyl p-hydroxybenzoate, 0.5mg Methyl p-hydroxybenzoate, 0.5mg Toluene, 9mg
Column used: Yamazen's Hi-Flash, L (30 gram) Fractionation mode: Peak mode separation



When running a large scale sample and/or a sample that has high UV absorption;
AI-580 A-2 type

Sample: Butyl p-hydroxybenzoate, 500mg Methyl p-hydroxybenzoate, 500mg Toluene, 900mg
Column used: Yamazen's Hi-Flash, 2L (45 gram)   Fractionation mode: Peak mode separation



     It's possible to get a slow gradient from 1% to 7% of polar solvent.

AI-580 A-2 type

A solvent delivery pump is of high precision medium pressure valveless ceramic piston pump, featuring infinite fine flow adjustments. The gradient at low concentration of solvent as low as 1 to 7% is possible, which is required when using a high polar solvent, like methanol, without pre-mixing.

Effective ceramic piston movement for maximum solvent and bubble clearing, assuring accurate solvent delivery. Bubbles produced by solvents that have low boiling points like dichloromethane will not affect pump.



Specifications

Solvent Delivery Pump
Model No.580
Flow rate 0-80ml/min
Rated pressure 1.0Mpa (145 psi)
No. of Solvent Mixed 2 (Choose from 4 solvents)
Dimension 180Wx394Dx250mmH
Weight 10kg
Fixed Wavelength UV Detector
Model prepUV-254
Light source Hg lamp
Wavelength 254nm
Range O.D. 0.08-5.12
Output to recorder 10mVFS
Output to integrator 0-5.12V/AU
Out to D-sub Purpose-built signal
Dimension 180Wx394Dx135mmH
Weight 6kg
Variable Wavelength UV Detector
Model prepUV-10V
Light source D2 lamp
Wavelength 190-350nm
Range O.D. 0.08-5.12
Output to recorder 10mVFS
Output to integrator 0-5.12V/AU
Out to D-sub Purpose-built signal
Dimension 180Wx460Dx135mmH
Weight 10kg
UV Visible Detector
Model prepUV-VIS-10V
Wavelength 190-600nm
Fraction Collector
Model FR-360
No. of Rack 2 (A pair of the same size racks)
Driving mode X-Y driven
Fraction mode Time, Peak, Peak & Slope (Valley), Manual Collect
Input signal Purpose-built signal
Dimensions 300WX430DX520mmH
Weight 18kg
System Controller (built into Fraction Collector)
Input/Output Signal Pump, Detector, Fraction collector, PC dedicated
PC Specifications
OS Windows
CPU Pentium III or Celeron with 500MHz or more is recommended.
Memory 512MB or more
Monitor XGA or higher resolution recommended
Hard Disk Space Min 500MB of available memory
Input/Output Signal Serial RS232C D-sub 9 pin
* For more specifications of the PC, please inquire.

Standard Accessories

A pair of the same size rack

FR-360 Rack
118W x 335L x 159mmH

Note:FR-360 fraction collector holds a pair of the same size rack.
When ordering the rack, please specify it with Cat. Number.

Rack Specifications, Collection Tube (O.D. x Length x Quantity)
Cat. No.
Pin Code
Fraction Volume(Default)
American Standard Tube Size (mm)
AI13100
A
7ml
13x100x75 pieces
AI15125
A
12ml
15x125x75 pieces
AI16125
A
15ml
16x125x75 pieces
AI16150
A
16ml
16x150x75 pieces
AI18150
B
22ml
18x150x75 pieces
AI25150
C
45ml
25x150x30 pieces
AI25200
C
56ml
25x200x30 pieces
AI30200
D
100ml
*30x200x27 pieces
AI60180
E
350ml
*60x180x10 pieces
Note: Test tube with * is of Japanese standard.

Cat. No.
Pin Code
Fraction Volume(Default)
Japanese Standard Tube Size (mm)
AI15150
A
15ml
15x150x75 pieces
AI18180
B
30ml
18x180x75 pieces
AI24180
C
60ml
24x180x75 pieces
AI30180
D
90ml
30x180x27 pieces
AI30200
D
100ml
30x200x27 pieces
AI60180
E
350ml
60x180x10 pieces

Column Stand
Two types are available.
(1) Two square pillars installed parallel in front of pump
(2) Two round pillars installed parallel in front of pump

Fittings & Tubing

Options
Solvent Level Monitor
Waste Fluid Monitor
Column Air Purge Pump



download brochure(PDF) YFLC-AI-580 Series