NEW, Dual Channel Automated Flash Chromatography System

Smart Flash EPCLC W-Prep 2XY

Capabilities and Functions

  • Two AI-580's in one compact single system: double the power, parallel two independent channels
  • Capable of independent operation of each channel by a group or one person
  • User friendly, intuitive software and hardware
  • Auto setup of optimum chromatographic method
  • Predictable elution position(s) of target compound(s): at around end of the gradient or 4-column volume
  • Viewing the chromatogram in a broad OD range: No peak saturation and no sample loss
  • Accurate low (slow) gradient (1%-7% polar solvent)
  • Real time monitor of the line pressure for safe operation
  • This model saves floor space by putting solvent bottles on top of the system.
  • Column stand installed in front of pump/UV detector.
  • Two solvent bottles (A & B or C & D) can be put on top of the Fraction Collector, or four bottles on the bench beside the pump or on the floor.
  • Computer can be put on the bench beside the machine or outside of the safety cabinet.
Eco-Friendly

Fast, Efficient, Safe Operation

Eco-Friendly System

Designed with Safety in Mind.


Simple and User-friendly Software

Parallel and Independent Operation of Each Channel by a group or a single person.

Smart Flash EPCLC W-Prep 2XY
go to top

Two chromatograms (Ch-1 & Ch-2) can be viewed on the same display at the same time.

Smart Flash EPCLC W-Prep 2XY


To save floor space the solvent bottles are put on top of the system.

Smart Flash EPCLC W-Prep 2XY


W-Prep 2XY A Type Basic System Configurations

  • Solvent Delivery Pump 580D, 3 - 80ml/min, 1.0 Mpa.
  • Fixed Wavelength UV detector, prepUV254W, 254nm with flow cell 0.2mm light path length (std.), 0.1mm light path length (option).
  • Variable Wavelength UV detector, prepUV-10VW (Option): 190 - 350nm with flow cell 0.2mm light path length (standard) 0.1 mm light path length (option).
  • Equipped with automatic external nozzle cleaning (Option) to prevent contaminations between runs.
  • Fraction Collector, FR-260A, XY driven parallel, double arm.
  • Column Stand, installed in front of Pump/UV detector.
  • A pair of test tube racks.
  • Laptop Tray, on top of Fraction Collector.
  • Operation Software included.
  • Without Laptop.
  • Floor space: 550mm W x 540mm D x 794mm H.

go to top

W-Prep 2XY A-type Specifications

Pump (with an integrated mixer)
Model No. 580D
Flow Path Two Flow Paths (Independently controlled)
Number of Pump Head Two (Independently controlled)
Flow Rate 0~80ml/min (Independently controlled by PC)
Rated Pressure 1.0 Mpa
Number of solvents mixed Two solvents (Selection from 4 solvents. PC controls each path independently.)
Dimensions 180Wx407Dx306mmH
Weight 10Kg
Fixed Wavelength UV Detector
Model No. prepUV-254W
Range O.D. 0.08-5.12
Flow Path Two (Independently controlled)
Light source Hg lamp
Wavelength 254nm
Output to recorder 10mVFS
Output to integrator 0-5.12V/AU
Out to D-sub Purpose-built signal
Dimensions 180Wx407Dx160mmH
Weight 7Kg
Variable Wavelength UV Detector
Model No. prepUV-10VW
Flow Path Two (Independently controlled)
Light source D2 lamp
Wavelength 190-350nm
Range O.D. 0.08-5.12
Output to recorder 10mVFS
Output to integrator 0-5.12V/AU
Out to D-sub Purpose-built signal
Dimensions (180Wx460Dx135mmH) X 2 ea
Weight 10Kg X 2ea
Fraction Collector
Model No. FR-260A
Detecting Flow Path Two (Independently controlled)
Number of Rack Two (One for each channel)
Driving mode X-Y driven, independently controlled, dual channel
Fraction mode Time Mode, Peak Mode, Peak & Slope mode
(Each rack is controlled independently by PC)
Input Signal Purpose-built signal
Dimensions 360Wx435Dx516mmH
Weight 22kg
System Controller (built into Fraction Collector)
Input/Output Signal Pump, Detector, Fraction collector, PC Serial Interface
PC Specifications
OS Windows XP, Vista
CPU Pentium III or Mobile Celeron with 500MHz or more is recommended.
Memory 256MB or more
Monitor Recommended XGA or higher resolution
Hard Disk Space At least 500MB of availability memory
Input/Output Signal Serial RS232C D-sub 9 pin or USB. (for USB, an adaptor is required)
Others CD-ROM Drive. Input device (Keyboard, Mouse)

go to top

Standard Accessories

FR-260 Rack
107Wx335Lx159mmH

FR-260 Fraction Collector holds two racks - either two of the same size rack for both channels or one each of the different size rack for each channel. Unless otherwise specified, two WP18150, 18x150mm racks, will be supplied with the system as standard accessory.

Note:
Specifications can change without notice.

Rack Specifications, Collection Tube (O.D. x Length x Quantity)
Cat. No.
Size Code
Fraction Volume(Default)
American Standard Tube Size (mm)
WP13100
A
7ml
13x100x60 pieces
WP15125
A
12ml
15x125x60 pieces
WP16125
A
15ml
16x125x60 pieces
WP16150
A
16ml
16x150x60 pieces
WP18150
B
22ml
18x150x60 pieces
WP25150
C
45ml
25x150x30 pieces
WP25200
C
56ml
25x200x30 pieces
WP20150
D
27ml
20x150x52 pieces
WP30200
E
100ml
*30x200x27 pieces
Note: Test tube with * is of Japanese standard (E-size).

Cat. No.
Size Code
Fraction Volume(Default)
Japanese Standard Tube Size (mm)
WP15150
A
15ml
15x150x60 pieces
WP18180
B
30ml
18x180x60 pieces
WP24180
C
60ml
24x180x30 pieces
WP21180
D
42ml
21x180x52 pieces
WP30180
E
90ml
30x180x27 pieces
WP30200
E
100ml
30x200x27 pieces


Fittings & Tubing

Options
Solvent Level Monitor
Waste Fluid Monitor
External Nozzle Cleaning System
Column Air Purge
TLC Image Reader


download brochure(PDF) YFLC-W-Prep 2XY


go to top