Intelligent & Eco-Friendly
Smart Flash EPCLC W-Prep 2XY
NEW, Dual Channel Automated Flash Chromatography System
Capabilities and Functions
- Two AI-580's in one compact single system: double the power, parallel two independent channels
- Capable of independent operation of each channel by a group or one person
- User friendly, intuitive software and hardware
- Auto setup of optimum chromatographic method
- Predictable elution position(s) of target compound(s): at around end of the gradient or 4-column volume
- Viewing the chromatogram in a broad OD range: No peak saturation and no sample loss
- Accurate low (slow) gradient (1%-7% polar solvent)
- Real time monitor of the line pressure for safe operation
- This model saves floor space by putting solvent bottles on top of the system.
- Column stand installed in front of pump/UV detector.
- Two solvent bottles (A & B or C & D) can be put on top of the Fraction Collector, or four bottles on the bench beside the pump or on the floor.
- Computer can be put on the bench beside the machine or outside of the safety cabinet.
Fast, Efficient, Safe Operation
Eco-Friendly System
Designed with Safety in Mind.
Simple and User-friendly Software
Parallel and Independent Operation of Each Channel by a group or a single person.
Two chromatograms (Ch-1 & Ch-2) can be viewed on the same display at the same time.
To save floor space the solvent bottles are put on top of the system.
W-Prep 2XY A Type Basic System Configurations
- Solvent Delivery Pump 580D, 3 - 80ml/min, 1.0 Mpa.
- Fixed Wavelength UV detector, prepUV254W, 254nm with flow cell 0.2mm light path length (std.), 0.1mm light path length (option).
- Variable Wavelength UV detector, prepUV-10VW (Option): 190 - 350nm with flow cell 0.2mm light path length (standard) 0.1 mm light path length (option).
- Equipped with automatic external nozzle cleaning (Option) to prevent contaminations between runs.
- Fraction Collector, FR-260A, XY driven parallel, double arm.
- Column Stand, installed in front of Pump/UV detector.
- A pair of test tube racks.
- Laptop Tray, on top of Fraction Collector.
- Operation Software included.
- Without Laptop.
- Floor space: 550mm W x 540mm D x 794mm H.
W-Prep 2XY A-type Specifications
Pump (with an integrated mixer) | |
Model No. | 580D |
Flow Path | Two Flow Paths (Independently controlled) |
Number of Pump Head | Two (Independently controlled) |
Flow Rate | 0~80ml/min (Independently controlled by PC) |
Rated Pressure | 1.0 Mpa |
Number of solvents mixed | Two solvents (Selection from 4 solvents. PC controls each path independently.) |
Dimensions | 180Wx407Dx306mmH |
Weight | 10Kg |
Fixed Wavelength UV Detector | |
Model No. | prepUV-254W |
Range | O.D. 0.08-5.12 |
Flow Path | Two (Independently controlled) |
Light source | Hg lamp |
Wavelength | 254nm |
Output to recorder | 10mVFS |
Output to integrator | 0-5.12V/AU |
Out to D-sub | Purpose-built signal |
Dimensions | 180Wx407Dx160mmH |
Weight | 7Kg |
Variable Wavelength UV Detector | |
Model No. | prepUV-10VW |
Flow Path | Two (Independently controlled) |
Light source | D2 lamp |
Wavelength | 190-350nm |
Range | O.D. 0.08-5.12 |
Output to recorder | 10mVFS |
Output to integrator | 0-5.12V/AU |
Out to D-sub | Purpose-built signal |
Dimensions | (180Wx460Dx135mmH) X 2 ea |
Weight | 10Kg X 2ea |
Fraction Collector | |
Model No. | FR-260A |
Detecting Flow Path | Two (Independently controlled) |
Number of Rack | Two (One for each channel) |
Driving mode | X-Y driven, independently controlled, dual channel |
Fraction mode | Time Mode, Peak Mode, Peak & Slope mode (Each rack is controlled independently by PC) |
Input Signal | Purpose-built signal |
Dimensions | 360Wx435Dx516mmH |
Weight | 22kg |
System Controller (built into Fraction Collector) | |
Input/Output Signal | Pump, Detector, Fraction collector, PC Serial Interface |
PC Specifications | |
OS | Windows XP, Vista |
CPU | Pentium III or Mobile Celeron with 500MHz or more is recommended. |
Memory | 256MB or more |
Monitor | Recommended XGA or higher resolution |
Hard Disk Space | At least 500MB of availability memory |
Input/Output Signal | Serial RS232C D-sub 9 pin or USB. (for USB, an adaptor is required) |
Others | CD-ROM Drive. Input device (Keyboard, Mouse) |
Standard Accessories
FR-260 Rack107Wx335Lx159mmH
FR-260 Fraction Collector holds two racks - either two of the same size rack for both channels or one each of the different size rack for each channel. Unless otherwise specified, two WP18150, 18x150mm racks, will be supplied with the system as standard accessory.
Note:
Specifications can change without notice.
Rack Specifications, Collection Tube (O.D. x Length x Quantity)
Cat. No. |
Size Code |
Fraction Volume(Default) |
American Standard Tube Size (mm) |
WP13100 |
A |
7ml |
13x100x60 pieces |
WP15125 |
A |
12ml |
15x125x60 pieces |
WP16125 |
A |
15ml |
16x125x60 pieces |
WP16150 |
A |
16ml |
16x150x60 pieces |
WP18150 |
B |
22ml |
18x150x60 pieces |
WP25150 |
C |
45ml |
25x150x30 pieces |
WP25200 |
C |
56ml |
25x200x30 pieces |
WP20150 |
D |
27ml |
20x150x52 pieces |
WP30200 |
E |
100ml |
*30x200x27 pieces |
Cat. No. |
Size Code |
Fraction Volume(Default) |
Japanese Standard Tube Size (mm) |
WP15150 |
A |
15ml |
15x150x60 pieces |
WP18180 |
B |
30ml |
18x180x60 pieces |
WP24180 |
C |
60ml |
24x180x30 pieces |
WP21180 |
D |
42ml |
21x180x52 pieces |
WP30180 |
E |
90ml |
30x180x27 pieces |
WP30200 |
E |
100ml |
30x200x27 pieces |
Fittings & Tubing
Options
Solvent Level Monitor
Waste Fluid Monitor
External Nozzle Cleaning System
Column Air Purge
TLC Image Reader
download brochure(PDF) YFLC-W-Prep 2XY